Back to top
COD1500 - COD Analyzer With Digestor Labman
COD1500 - COD Analyzer With Digestor Labman
COD1500 - COD Analyzer With Digestor Labman
COD1500 - COD Analyzer With Digestor Labman

COD1500 - COD Analyzer With Digestor Labman

COD1500 - COD Analyzer With Digestor Labman Specification

  • Port Size
  • Standard 16mm digestion tube compatibility
  • Operating Voltage
  • 230V AC, 50 Hz
  • Specimen Size
  • 2-10 mL sample volume
  • Display Type
  • Digital LCD Display
  • Humidity
  • 85% RH
  • Max Height
  • Approx. 400 mm with digestion tubes
  • Mounting Type
  • Table-top/Bench top
  • Automation Grade
  • Semi-automatic
  • Accuracy
  • 5% or better
  • Resolution
  • 1 mg/L
  • Equipment Type
  • COD Analyzer With Digestor
  • Interface Type
  • RS232 (standard), USB optional
  • Number of Specimens
  • 15 samples per batch
  • Temperature
  • Operating Temperature 5C - 45C
  • Frequency
  • 50 Hz
  • Test Range
  • 0-1500 mg/L COD (extendable up to 15000 mg/L with dilution)
  • Features
  • Microprocessor control, auto timer, digital readout, thermal insulation, sample protection
  • Measuring Range
  • 0-1500 mg/L COD (can be extended with dilution)
  • Gas Pressure
  • Ambient
  • Power Supply
  • AC 230V 10%, 50 Hz
  • Response Time
  • Reading within 5 seconds after digestion and cooling
  • Application
  • Determination of Chemical Oxygen Demand (COD) in water and wastewater
  • Usage
  • Laboratory analysis
  • Capacity
  • 15/24/36 tubes (varies by model)
  • Machine Weight
  • Approx. 5 kg (Analyzer), 6 kg (Digestor)
  • Test Speed
  • Varies as per protocol, typically 2 hours per batch
  • Control Mode
  • Digital Microprocessor-Based
  • Timer
  • Digital, 1-120 min programmable
  • Data Output
  • Printable reports, RS232 connectivity
  • Heating Block
  • Aluminium
  • Cooling Time
  • Typically 20-30 min after digestion
  • Safety Features
  • Over-temperature cut-off, thermal fuse
  • Tube Material
  • Borosilicate glass tubes
  • Standards Compliance
  • IS 3025 (Part 58), APHA 5220 D
  • Digestion Temperature
  • Reaches up to 150C 1C
 
 

About COD1500 - COD Analyzer With Digestor Labman



Highlighted as the dominant solution in water and wastewater analysis, the COD1500 - COD Analyzer With Digestor Labman is ending soon at an unbeatable price. This majestic and exceptional analyzer offers unmatched accuracy (5% or better), with a digital microprocessor-based control for easy handling. Its borosilicate glass tubes and aluminium heating block ensure dependable digestion up to 150C. Designed with comprehensive safety, compliance to IS 3025 (Part 58)/APHA 5220 D, and rapid, printable data output, it manages up to 15 samples per batch-delivering laboratory-grade reliability every time.

Exceptional Features and Versatile Application Areas

The COD1500 - COD Analyzer With Digestor Labman comes loaded with extra features like programmable digital timer, auto thermal cut-offs, printable reports, and robust sample protection. Its semi-automatic design makes it ideal for analytical labs, municipal water testing centers, research institutions, and industrial facilities requiring precise COD measurement. Its adaptability, with digital controls and variable tube capacity options, ensures efficient operation across diverse application areas involving environmental monitoring and water quality assessment.


Sample Policy, Market Valuation, and Payment Terms

Our sample policy for the COD1500 ensures fair valuation and competitive outlay, making the process smooth for prospective buyers. We cater to a broad domestic market across India, guaranteeing fast freight delivery and robust after-sales support. Flexible payment terms are available, accommodating various business needs for maximum convenience. Whether as an exporter, manufacturer, or supplier, we ensure a seamless purchasing experience for all laboratory analysis requirements.


FAQ's of COD1500 - COD Analyzer With Digestor Labman:


Q: How does the COD1500 - COD Analyzer With Digestor ensure accurate and safe operation?

A: The analyzer utilizes a digital microprocessor-based control, borosilicate glass tubes for reliability, and multiple safety features such as over-temperature cut-off and thermal fuse. This ensures precise digestion and optimal operator safety.

Q: What type of laboratories or industries benefit most from this analyzer?

A: Labs involved in water quality testing, municipal wastewater facilities, research centers, and industrial plants greatly benefit, as the device is tailored for high-throughput and dependable COD determination.

Q: When can operators expect test results after starting a batch analysis?

A: After digestion and cooling, sample readings are available within 5 seconds, typically completing one batch in nearly 2 hours depending on protocol requirements.

Q: Where can this equipment be set up for optimal usage?

A: Its table-top or bench-top design allows for easy installation in laboratory environments, ensuring safe handling and efficient workspace utilization.

Q: What is the process for data output and report generation?

A: After the digestion cycle, the analyzer offers printable reports and supports RS232 connectivity, with optional USB interface for flexible data management and record-keeping.

Q: How does the sample capacity and specimen size enhance lab productivity?

A: The analyzer can process up to 15 samples per batch, with specimen sizes ranging from 2-10 mL, maximizing throughput and efficiency for busy laboratory settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Water Testing Equipments Category

BOD4000 -BOD Analyzer Labman

BOD4000 -BOD Analyzer Labman

Usage : Laboratory, Research, Wastewater Analysis

Equipment Type : BOD Analyzer

Features : Automatic temperature compensation, Builtin memory, Automatic data logging

Application : BOD estimation for water & wastewater samples in laboratories

KFT250VC Karl Fischer Titrator Labman

KFT250VC Karl Fischer Titrator Labman

Price 470000 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Water content titration

Equipment Type : Karl Fischer Titrator

Features : Automatic drift compensation and error messages

Application : Laboratory Use

LMCM20H Conductivity TDS Labman

LMCM20H Conductivity TDS Labman

Usage : Laboratory / Field Analysis

Equipment Type : Conductivity / TDS / Temperature Meter

Features : Auto Temperature Compensation (ATC), Auto Range, Data Hold, Backlight, Low Battery Indication

Application : Measurement of conductivity, TDS, salinity and temperature in liquids

LovibondDpd Tablets No 1 For Water Testing

LovibondDpd Tablets No 1 For Water Testing

Price 2000 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Water Testing

Equipment Type : DPD Reagent Tablet

Features : Analytical grade reagents

Application : Water Testing