Hanna Instruments HI 96107 pH meter 85 G Specification

  • Display Type
  • Digital LCD
  • Power Supply
  • 3 1.5 V Battery
  • Accuracy
  • 0.1 pH pH
  • Usage
  • Laboratory
  • Type
  • Other
  • Dimension (L*W*H)
  • 150 30 21 mm Millimeter (mm)
  • Height
  • Approx. 15 cm Centimeter (cm)
  • Product Type
  • Digital pH Meter
  • Equipment Type
  • Portable pH Meter
  • Weight
  • 85 g as listed for the TradeIndia product Grams (g)
  • Equipment Materials
  • Portable pH Meter
  • Width
  • Approx. 3 cm Centimeter (cm)
  • Voltage
  • 1.5 V each kilovolt (kV)
  • Application
  • Laboratory
  • Warranty
  • Verify supplier/manufacturer warranty before listing
 

Hanna Instruments HI 96107 pH meter 85 G Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 1 Piece Per Day
  • Delivery Time
  • 1 Days
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • BOX
  • Main Export Market(s)
  • Asia, Australia, Central America, South America, Eastern Europe, Western Europe, Middle East, Africa, North America
  • Main Domestic Market
  • All India
  • Certifications
  • HANNA
 

Hanna Instruments HI 96107 pH meter 85 G About

Before using Hanna products, make sure that they are entirely suitable for your specific application and for the environment in which they are used. Operation of these instruments may cause unacceptable interferences to other electronic equipment, thus requiring the operator to take all necessary steps to correct such interferences. Avoid touching the probes at all times. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid damages or burns, do not put the instrument in microwave oven. For yours and the instrument safety do not use or store the instrument in hazardous environments.Operational Guide 
  • Remove the protective cap. Do not be alarmed if white crystals appear around the cap. This is normal with pH electrodes and they dissolve when rinsed with water. 
  • Turn the meter on sliding the switch on the top. 
  • Immerse into solution up to the max immersion level. 
  • Stir gently and wait until the display stabilizes. 
  • After use, rinse the electrode with water to minimize contamination and store it with a few drops of storage (HI70300) or pH 7 (HI 7007) solution in the protective cap. 
  • Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.
The meter is warranted for a period of six months against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna office. If under warranty, report the model number, date of purchase, serial number and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization (RGA) number from the Technical Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection.

Calibration
  • Immerse the tester up to the maximum immersion level in pH 7 buffer (HI 7007) 
  • Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 7.0. 
Battery Replacement
When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5V batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Instruments Category

RQ-128D D Stainless Steel Laboratory Stirrer

RQ-128D D Stainless Steel Laboratory Stirrer

Price 19500 INR / Unit

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 350 x 220 x 175 mm

Shape : Rectangular

Temperature Resistance : Up to 120C

Control Type : Rotary Knob

Labman RCB1010T Refrigerated Circulating Bath

Labman RCB1010T Refrigerated Circulating Bath

Price 100000 INR / Unit

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 54 x 58.4 x 81.3 cm

Shape : Rectangular

Temperature Resistance : 10C to 100C

Control Type : Microprocessor PID controller

RCB620T Labman Refrigerated Circulating Bath

RCB620T Labman Refrigerated Circulating Bath

Price 135000 INR / Unit

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : Packing: 540 x 470 x 550 mm, Tank: 350 x 165 x 130 mm

Shape : Horizontal

Temperature Resistance : 20C to 100C

Control Type : Microprocessor PID

BENNY Double Tested Laboratory Thermometer

BENNY Double Tested Laboratory Thermometer

Price 250.0 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : Standard Laboratory Size

Shape : Straight, Cylindrical

Temperature Resistance : Up to 110C (as per typical laboratory thermometer)

Control Type : Manual Reading